Normalizing Applications
API 5L pipe specifications
Pressure vessel components
Structural members requiring enhanced toughness
Annealing Requirements
Cold-worked materials requiring recrystallization
Stainless steel weld seam restoration
Copper alloy stress relief
System Configuration
Induction heating coils immediately follow the weld point. Temperature control systems maintain precise thermal profiles through PID controllers. Cooling sections utilize air or water mist systems depending on material requirements.
Operational Parameters
Heating temperature: 700-950°C
Retention time: 15-90 seconds
Cooling rate: 2-20°C/second
Atmosphere control: Nitrogen shielding for oxidation prevention
Quality Verification
Hardness testing across the weld zone ensures proper heat treatment. Microstructure examination verifies grain size and phase distribution. Impact testing confirms toughness properties meet specification requirements.